skip to Main Content
LOGO_APID-280x59

These restore the power of P-TYPE solar cell modules,
stop the economic damage caused by PID
and prevent the onset of the phenomenon in new systems.

Benefits

Power

Stops the loss of power in the solar system.

Profitability

Stops the economic damage caused by Potential Induced Degradation and ensures the profitability of the solar system.

Regeneration

Regenerates the power of solar systems by up to 100% in around 30 days.

Prevention

Prevents photovoltaic PID, from the first day of life.

Protection

Immediately protects new systems with PID-Free modules from a possible drop in power by up to 5%

Resistance

Measures the insulation resistance

APID Details – APID 3

Details
APID APID 3

Photovoltaic system

EXISTING

NEW

Photovoltaic system

EXISTING

During the Day

STANDBY
Monitoring and storing voltages at MPPT inputs

Recovery of power

PID prevention

Overnight

Recovery of power

Monitoring: operation of the APID generator, string voltage, insulation resistance

WORK
APID generator operation, insulation resistance measurement, voltage monitoring and storage on MPPT inputs

Photovoltaic system

NEW

During the Day

Operating mode: standby
Monitoring: voltage on MPPT input
Archive: historical storage

Overnight

PID prevention

Monitoraggio: funzionamento generatore APID, tensione stringa, resistenza isolamento

Operation Apid and Apid 3 in 24h

Connection diagram Apid and Apid 3

APID

APID 3

For photovoltaic modules with model

P-Type cells

MPPT outputs

2

3

MPPT outputs

APID: 2 – APID 3: 3

Power supply

90.275 Vac

Power consumption

< Standby 0.5w Operating 2W, Maximum 20W

Internal generator

Voltage with output resistance of 165K Max. 1000 Vdc output power 2.7mAMax at 1000v – 3.9mA Max. at 800v – 6.3mA Max. at 400V – 8mA in short circuit

Automatic management of operation and output voltage

Yes

Relay output with NC and NA contacts for alarm signalling

Yes

Clock/Calendar with 6 months backup

Yes

Anti-condensation valve

ØM12 F16 litres/hour at 0.07 bar

Connections to the MC4 strings

MC4

Dimensions

240x190x90

Container type

IP56

Operating temperature

-20 °C/+50 °C

Weight

950 g

Why you should choose APID or APID-3

Investment Funds/Owners

Asset protection and guaranteed ROI

Financial Institutions

Credit protection

Asset Managers

Strategic management of the solar investment

Insurance

Protection of the warranty given

EPC

Ensuring the design and maintenance of a profitable system.

O&M

For recovering systems with loss of power.
Maintenance at maximum possible yield.

Design studies

Design systems intrinsically protected from the risk of loss of power (up to 5%) for the PID-FREE modules.

Solar-system installers

Generate new and exclusive business opportunities

Energy managers

Ensure maximum yield of the solar system

Technical consultants

Offer a definitive and technologically-advanced solution

Solar module manufacturers

Guarantee 100% PID-FREE modules. Provide support to customers with older-generation systems.

Inverter manufacturers

Offer a technical solution to customers with PID issues.